Inverter Variable Speed Drive For Hurricane Commercial Pool Pump Below 3HP
CODE: CVSD01HUR- Inverter Variable Speed Drive For Hurricane Commercial Pool Pumps Below 3HP
- Payback potentially less than 6 months
- Suitable For Pumps Up To But Not Including 3HP - 3 Phase
- Can be linked to BMS
- Keypad controls
- Up to 50°C operating conditions
- Easy to install and programme
- Also Available For BP Range, BPH Range, Calpeda, Modern, Hurricane, Giant, Great Giant, Hydrostar, Columbia, Aral, Maxim, Shark, Speck, Hayward, Waterco, Starite and DAB
DELIVERY: We aim to send all products out on a next working day service but all standard deliveries will be within 5 working days
RETURNS: This product can be returned in original packaging, suitable for resale, within 14 days from date of delivery. Returns should be sent via a "Signed For" carrier or post.
When we receive the item, our returns department confirm that everything is present and in its in original condition to ensure its eligibility for refund. We process refunds as quickly as possible. We process most refunds on the same day which they were received, but please allow up to a maximum of 14 days for the money to reach your account. It rarely takes this long, but can happen sometimes for reasons such as bank delays or errors.
PRODUCT INFO:
Inverter Variable Speed Drive For Hurricane Commercial Pool Pumps below 3HP is a solution designed to greatly reduce the running costs of commercial pool circulation pumps and improve the efficiency of swimming pool filtration.
Swimming pool pumps invariably run at higher flow rates than necessary, to allow for the power needed when backwashing. Inverter Variable Speed Drive For Hurricane Commercial Pool Pumps Up To 3HP Inverter technology enables you to control pump flow-rates during the filtration period, which is over 95% of the time.
Swimming pool pump energy conservation is evolving, it’s now possible to reduce the running costs of your commercial pool pump by as much as 33% simply by reducing your pump speed to 80% for 95% of the time and the running it at 100% power while backwashing for the remaining 5% of the time.
We Have Inverter Variable Speed Drives Suitable For The Following Pumps:
BP Range, BPH Range, Calpeda, Modern, Hurricane, Giant, Great Giant, Hydrostar, Columbia, Aral, Maxim, Shark, Speck, Hayward, Waterco, Starite and DAB
Just search our website to find yours or call us on 01322 554 870 for us to assist choosing the correct model.
How does it work?
Example of cost saving Pump size 2.5HP (1.865kW) 3 phase pump.
Operating time 24 hours / 7 days a week / 52 weeks- Running Costs £5,540 Per Year
Cost of unit £891.00
Suggested Cost of installation £350.00
Total cost £1241.00
Based on electricity at 34p per kWh
The cost of running the pump at 80% of the speed for 95% of time and 100% of speed for 5% (backwash) is £4055 Per Annum.
Cost saving is £123.75 per month and 10 months payback on installation.
Understanding Pump Affinity Laws
Understanding pump affinity laws will allow you to explain, demonstrate and calculate how a change in motor speed impacts;
• flow rates against resistance
• power consumption
• operating costs
1. The change in flow is proportionate (equal) to the change in speed. If we halve the speed we halve the flow
2. The change in pressure is equal to the speed change factor squared. Operating pressure will be 1/4 of the original pressure
3. The change in power consumption is equal to the speed change factor cubed. Power consumption will be 1/8 the original consumption
As an example, if we take a pump with the following characteristics:
• Motor speed: 2850 rpm
• Flow rate: 302 lpm
• Pressure: 8 metres head
• Power input: 983 Watts
We set the low speed at 1900 rpm – a reduction factor of 0.67 - 1900 ÷ 2850 = 0.67 Applying the factor 0.67 to all pump affinity laws we can determine the pumps operating characteristics at the new speed on 1900 rpm.
1. The change in flow is proportionate (equal) to the change in speed. 302 x 0.67 = 202 lpm
2. The change in pressure is equal to the speed change factor squared. 8 x 0.67 x 0.67 = 3.6 metres head
3. The change in power consumption is equal to the speed change factor cubed. 983 x 0.67 x 0.67 x 0.67 = 295 watts
Therefore, the pump has these new low speed operating characteristics:
• Motor speed: 1900 rpm
• Flow rate: 202 lpm
• Pressure: 3.6 metres head
• Power input: 295 watts
If you would like help choosing the correct Inverter Variable Speed Drive For Your Pool, Please Call Us On 01322 554 870